GE Series 90 PLC Error Codes

Top  Previous  Next

The following list of error codes can be returned from the PLC in response to requests from the GEE driver.

 

Decimal

Hex

Description

256

0100

Illegal service request code.

517

0205

Insufficient privilege level - read-only access allowed.

764

02FC

Insufficient privilege level - debug session active.

765

02FD

Insufficient privilege level - memory restricted.

766

02FE

Insufficient privilege level - access denied due to keyswitch

767

02FF

Insufficient privilege level - access denied due to OEM protection.

768

0300

Service request protocol timeout.

1024

0400

Service request protocol sequence error.

1535

05FF

Service request has been aborted.

1534

05FE

No privilege for attempted operation.

1533

05FD

Unable to perform auto configuration.

1532

05FC

I/O configuration is invalid.

1531

05FB

Cannot clear I/O configuration.

1530

05FA

Cannot replace I/O module.

1529

05F9

Task address out of range.

1528

05F8

Invalid task name referenced.

1527

05F7

Required to log in to a task for service.

1526

05F6

Invalid sweep state to set.

1525

05F5

Invalid password.

1524

05F4

Invalid input parameter in request.

1523

05F3

I/O configuration mismatch.

1522

05F2

Invalid program cannot log in.

1521

05F1

Request only valid from programmer.

1520

05F0

Request only valid in stop mode.

1519

05EF

Programmer is already attached.

1518

05EE

Could not return block sizes.

1517

05ED

VMEbus error encountered.

1516

05EC

Task unable to be created.

1515

05EB

Task unable to be deleted.

1514

05EA

Not logged in to process service request.

1513

05E9

Memory Type selector not valid in context.

1512

05E8

No user memory is available to allocate.

1511

05E7

Configuration is not valid.

1510

05E6

CPU model number does not match.

1509

05E5

DOS file area not formatted.

1508

05E4

Memory Type for this selector does not exist.

1507

05E3

CPU revision number does not match.

1506

05E2

IOS could not delete configuration or bad type.

1505

05E1

No I/O configuration to read or delete.

1504

05E0

Service in process cannot login.

1503

05DF

Invalid datagram connection address.

1502

05DE

Size of datagram connection invalid.

1501

05DD

Unable to locate given datagram connection ID.

1500

05DC

Unable to find connection address.

1499

05DB

Invalid Memory Type selector in datagram.

1498

05DA

Null pointer to data in Memory Type selector.

1497

05D9

Transfer type invalid for this Memory Type selector.

1496

05D8

Point length not allowed.

1495

05D7

Invalid datagram type specified.

1494

05D6

Total datagram connection memory exceeded.

1493

05D5

Invalid block name specified in datagram.

1492

05D4

Mismatch of configuration checksum.

1491

05D3

User Program Module (UPM) read or write exceeded block end.

1490

05D2

Invalid write mode parameter.

1489

05D1

Packet size or total program size does not match input.

1488

05D0

One or more PLC modules configured have unsupported revision.

1487

05CF

Specified device is not available in the system (not present).

1486

05CE

Specified device has insufficient memory to handle request.

1485

05CD

Attempt was made to read a device but no data has been stored on it.

1484

05CC

Data stored on device has been corrupted and is no longer reliable.

1483

05CB

A comm or write verify error occurred during save or restore.

1482

05CA

Device is write-protected

1481

05C9

Login using non-zero buffer size required for block commands

1480

05C8

Password(s) already enabled and cannot be forced inactive.

1479

05C7

Passwords are set to inactive and cannot be enabled or disabled.

1478

05C6

Control Program (CP) tasks exist but requester not logged into main CP.

1477

05C5

No task-level Rack/Slot configuration to read or delete.

1476

05C4

Verify with FA Card or EEPROM failed.

1475

05C3

Text length does not match traffic type.

1474

05C2

The OEM key is NULL (inactive).

1473

05C1

Invalid block state transition.

1536

0600

Illegal service request traffic types.

2043

07FB

Already waiting for service response.

2044

07FC

Memory read or write blocking this request.

2045

07FD

Another device owns the semaphore for a single execution request.

2046

07FE

Waiting for transfer traffic from another device.

2047

07FF

Service request queues full, try later

2048

0800

Service request queue overflow.

2304

0900

CPU busy with transfer from another device.